HIOKI DIGITAL MULTIMETER DT4282

HIOKI DIGITAL MULTIMETER DT4282

Category: Digital Multimeter

Specifications
Details

DIGITAL MULTIMETER DT4282




World's Premier Digital Multimeter! Superior Accuracy and High Response, Topped with Safety Terminal Shutters

The Hioki DT4200 Digital Multimeter Series consist of a complete lineup of 9 models ranging from professional to industrial to pocket types. The DT4282 is a high-precision 60,000 count digital multimeter with direct 10A input and all of the functions and features required for advanced testing in laboratories and R&D.

CAT IV 600 V, CAT III 1000 V
 

Key Features

  • 60000 count, 5-digit display, high-resolution measurements
  • ±0.025% DC V basic accuracy, wide 20 Hz to 100 kHz AC V frequency characteristics
  • Low-pass filter cuts high harmonics (when measuring inverter fundamental waveforms)
  • Terminal shutter mechanism (prevents erroneous test lead insertion)
  • Measure up to 10 A with direct input (DT4282 only)
  • Dual display lets you check voltage and frequency simultaneously
 

Basic specifications

Accuracy guaranteed: 1 year
Regarding DMM Accuracy: Due to the many ranges and functions available in a DMM, only the basic accuracy is indicated for reference. Please refer to the brochure for detailed accuracy information.
 
DC Voltage Range 60.000 mV to 1000.0 V, 6 ranges
Basic accuracy: ±0.025% rdg. ±2 dgt.
AC Voltage Range 60.000 mV to 1000.0 V, 6 ranges
Frequency characteristics: 20 Hz - 100 kHz
Basic accuracy 45 - 65 Hz: ±0.2% rdg. ±25 dgt. (True RMS, crest factor 3)
DC + AC Voltage Range 6.0000 V to 1000.0 V, 4 ranges
Frequency characteristics: 20 Hz - 100 kHz
Basic accuracy 45 - 65 Hz: ±0.3% rdg. ±30 dgt. (True RMS, crest factor 3)
Resistance Range 60.000 Ω to 600.0 MΩ, 8 ranges
Conductance: 600.00 nS (DT4282 only)
Basic accuracy: ±0.03% rdg. ±2 dgt.
DC Current Range 600.00 μA to 10.000 A, 6 ranges
Basic accuracy: ±0.05% rdg. ±5 dgt.
AC Current Range 600.00 μA to 10.000 A, 6 ranges
Basic accuracy 45 - 65 Hz: ±0.6% rdg. ±5 dgt. (True RMS, crest factor 3)
Frequency characteristics: 20 Hz - 20 kHz (at 600 μA to 600 mA range)
AC Current Range (with Clamp Probes) N/A
Peak DC V measurement: Signal width 4 msec or more (single), 1 msec or more (repeated)
AC V, DC/AC A measurement: Signal width 1 msec or more (single), 250 μsec or more (repeated)
Capacitance Range 1.000 nF to 100.0 mF, 9 ranges
Basic accuracy: ±1.0% rdg. ±5 dgt.
Continuity Check Continuity threshold: 20/50/100/500 Ω
Response time: 10 ms or more
Diode Test Open terminal voltage: 4.5 V or less
Testing current: 1.2 mA or less
Threshold of forward voltage: 0.15 V to 3 V, seven stages
  • *Zero-suppression: For small inputs below the guarantee range, zero is effectively displayed.

View more about HIOKI DIGITAL MULTIMETER DT4282 on main site