HIOKI LEAK CURRENT HiTESTER ST5541

HIOKI LEAK CURRENT HiTESTER ST5541


Specifications
Details

LEAK CURRENT HiTESTER ST5541

Leak Current Measurement, an Essential Part of Electrical Safety (for electrical devices)



To ensure the safe use of electrical products, electrical safety tests such as insulation resistance, withstand voltage, ground resistance, and leakage current must always be conducted. Hioki Leakage Current Testers comply with laws and standards regarding medical electrical equipment as well as non-medical electrical equipment, and can be used to measure leakage current in all types of electrical products from computers to medical equipment. The Hioki ST5541 provides support for standard-compliant networks (excluding medical-use electrical devices).

Key Features
• Compliance with Electrical Appliances and Materials Safety Act, JIS/IEC/UL standards
• Uninterrupted polarity switching function dramatically reduces cycle time
• Support for rated currents up to 20 A gives the instrument more than adequate capability for testing products designed to comply with new standards
• Touch panel features simple, interactive operation
• Communications functionality and external I/O support allow automatic testing on production lines


Measurement methods Measurement of voltage drop across body simulated resistance points, Calculation and display of current values, True rms measurement, Measurement unit floats relative to instrument ground.
Measurement modes Leak current measurement, voltage measurement, safety conductor current measurement
Standards compliance (NW: Body simulated resistance) [NW-A] • Electrical Appliances and Materials Safety Act
[NW-C]
• Measurement of touch current and protective conductor current: IEC 60990:2016
• Electrical equipment for measurement, control, and laboratory use: IEC 61010-1:2010+ A1:2016
• Information technology equipment: IEC60950-1:2005+ A1:2009+ A2:2013
• Audio, video and similar electronic apparatus: IEC 60065:2014
• Personnel Protection Systems for EV: UL 2231-1:2012 (Amended 2016), UL-2231-2:2012 (Amended 2016)
[NW-D] • For UL: UL 1492:1996 (Amended 2013)
[NW-G] • Electrical equipment for measurement, control, and laboratory use; current measurement circuits in damp conditions: IEC 61010-1:2010+ A1:2016
Leak current measurement Ground leak current, 3 types of contact current, free current measurement, 3 types of enclosure leak current
Measurement current DC, AC (true rms, 15 Hz to 1 MHz), AC+DC (true rms, 15 Hz to 1 MHz), AC peak (15 Hz to 1 MHz)
Measurement ranges DC / AC / AC+DC mode: 50.00 mA/ 5.000 mA/ 500.0 μA/ 50.00 μA
AC peak mode: 75.0 mA/ 10.00 mA/ 1.000 mA/ 500.0 μA
Measurement accuracy (current measurement) DC measurement: ±2.0% rdg. ±6 dgt. (typ.)
AC / AC+DC measurement: ±2.0% rdg. ±6 dgt. (15 Hz to 100 kHz, typ.)
AC peak measurement: ±2.0% rdg. ±6 dgt. (15 Hz to 10 kHz, typ.)
Interfaces External I/O, USB 1.1 (communications), RS-232C
Functionality Automatic test, data storage for 100 target devices, clock, data backup, printed output (optional), etc.
Power supply 100/120/220/240 V AC (specify at time of order), 50/60 Hz, 30 VA rated power
Target device power supply input 100 to 250 V AC, 50/60 Hz, Rated current input from terminal block: 20 A
Target device power supply output Output from terminal block: 20 A, Output from outlet: 15 A
Dimensions and mass 320 mm (12.60 in) W × 110 mm (4.33 in) H × 253 mm (9.96 in) D, 4.5 kg (158.7 oz)
Accessories Test lead L2200 (Red ×1, Black ×1) ×1 set, Enclosure probe 9195 ×1, Power cord ×3, Spare fuse for measurement line ×1, Instruction manual ×1, User guide ×1, CD-ROM ×1

■ ST5540, ST5541 List of functions (Network)

Item ST5540 ST5541
Network A (Electrical Appliances and Materials Safety Act)
Network B (Medical-use electrical devices) -
Network C (IEC 60990)
Network D (UL)
Network E (General-purpose 1)
Network F (General-purpose 2)
Network G (IEC 61010-1)

■ List of functions (Major functions)

Item ST5540 ST5541
Power on polarity switching function
Rated current 20 A
Function for checking for blown fuses
Frequency band switching -
110% voltage output terminal (T3 terminal) -
S10, S12, S13, E terminal -

■ List of functions (Testing leakage current mode)

Item ST5540 ST5541
Earth leakage current
Touch current
Patient auxiliary current -
Patient leakage current -
Total patient leakage current -
Free current
Enclosure - Earth leakage current
Enclosure - Enclosure leakage current
Enclosure - Line leakage current
Patient leakage current I -
Patient leakage current II -
Patient leakage current III -


View more about HIOKI LEAK CURRENT HiTESTER ST5541 on main site