Details
FLIR CM275 IGM™ Clamp Meter with Datalogging
The FLIR CM275 clamp meter combines thermal imaging with electrical measurement into powerful inspection, troubleshooting, and diagnostic tools. Through Infrared Guided Measurement (IGM), the CM275 provides a reliable way to identify hot spots and overloaded circuits from a safe distance. Confirm your findings with the clamp meter’s wide range of functions plus temperature readings. The FLIR CM275 also provides wireless connectivity to upload images or data to the FLIR Tools™ app.
SPECIFICATIONS
- IR Resolution
- 160 × 120 (19,200 pixels)
- Display Size
- 2.4 in TFT screen
- AC/DC Voltage
- Range 1000V / Basic Accuracy ±1.0%
- AC Current
- Range 600.0A / Basic Accuracy ±2.0%
- Data Logging & Storage
- 10 sets of 40K scalar measurements, 100 images
- Connectivity
- Bluetooth®
IMAGING & OPTICAL
- Color Palettes
- Iron, Rainbow, Grayscale
- Display Size
- 2.4 in TFT screen
- Field of View [V x H]
- 44° × 57°
- Focus
- Fixed
- Gallery
- 8549
- IR Resolution
- 160 × 120 (19,200 pixels)
- Sensitivity
- 150 mK
- Thermal Imaging Detector
- FLIR Lepton® microbolometer
MEASUREMENT & ANALYSIS
- AC Current
- Range 600.0A / Basic Accuracy ±2.0%
- AC/DC Voltage
- Range 1000V / Basic Accuracy ±1.0%
- Auto Range
- Yes, with manual range option
- Capacitance
- Range 1000µF / Basic Accuracy ±1.0%
- Continuity check threshold
- 30Ω to 150Ω
- Diode
- Range 1.5V / Basic Accuracy ±1.5%
- Flex Input AC A
- Range: 3000 A Basic Accuracy: ±1.0%
- Flex Input Frequency Counter
- Range: 10.00 kHz Basic Accuracy: ±0.1%
- Inrush AC Current
- Range 600.0A / Basic Accuracy ±3.0%
- LoZ Mode AC Voltage
- Range: 60.00 V, 600.0 V, 1000 V Basic Accuracy: ±1.0%
- LoZ Mode DC Voltage
- Range: 60.00 V, 600.0 V, 1000 V Basic Accuracy: ±1.0%
- Measuring Rate
- 3 samples per second
- Resistance
- Range 6000Ω / Basic Accuracy ±1.0%
- Temperature Accuracy
- ± 3°C (5.4°F) or ±3% of rdg
- Temperature Range
- 14°F to 302°F (-10°C to 150°C)
- True RMS
- Yes
- VFD AC Current
- Range 600.0A / Basic Accuracy ±2.0%
- VFD AC Voltage
- Range 1000V / Basic Accuracy ±1.0%
COMMUNICATION & DATA STORAGE
- Connectivity
- Bluetooth®
- Data Logging & Storage
- 10 sets of 40K scalar measurements, 100 images
POWER
- Auto Power Off
- Yes
- Battery
- 3 AA batteries; optional TA04 Li-Poly rechargeable battery
GENERAL
- Size (L x W x H)
- 43 x 89 x 241 mm (1.7 x 3.5 x 9.5 in)
- Weight
- 426 g (15 oz)
- Worklights
- Yes
ENVIRONMENTAL & CERTIFICATIONS
- Drop test
- 2 m
- Emissivity Settings
- 4 Presets with Custom Adjustment
View more about FLIR CM275 IGM Clamp Meter with Datalogging on main site