WIRELESS LOGGING STATION LR8410
Wireless Multi-channel Data Logger Captures Up to 105 Data Points via Bluetooth®
Hioki Memory HiLoggers are high-speed data loggers for recording multiple channels of voltage, temperature, resistance or humidity signals, some models providing complete isolation between channels and strong noise resistance. The LR8410-20 is an innovative wireless logging system capable of capturing up to 105 channels of data wirelessly using Bluetooth® wireless technology. SD Card bundled
Key Features
• Capture logging data using Bluetooth® wireless technology. Install logging modules in hard-to-reach locations (over line-of-sight distances of up to 30 meters *1 ) (*1) The presence of obstructions may shorten this range. In addition, radio wave intensities, which are indicated with the antenna-like indicators, vary depending on units even while these units are operating in the same environment.
• Measurement units have built-in buffer memory so that measurement data can be saved if communication is temporarily disrupted.
• Choose an input unit based on the parameters you wish to measure (15-channel and 2-channel units are available)
• Easily add up to 7 input units wirelessly to keep your environment free of tangled wires (for a total of up to 105 channels when using 15-channel units)
• 100 msec simultaneous sampling across all channels using rapid scanning method
• Quick Set guide makes configuration a breeze
• Can receive data from LR8410 Link compatible products (Ver. 1.40 or later)
LR8410-20 | English model, main unit only |
---|
The LR8410-20 alone is not capable of making measurements. One or more input modules are necessary to measure. The main unit and input modules are not bundled with the Battery Pack Z1007. Thermocouples are not provided by HIOKI, and must be purchased from a separate vendor. Note: Use only HIOKI SD Memory card, which is manufactured to strict industrial standards, for long-term storage of important data. Correct operation of non-HIOKI SD cards or USB memory sticks are not guaranteed. *Models LR8512 to LR8515 may only be used in countries in which they have been certified. These products emit radio waves. Use of radio waves is subject to licensing requirements in certain countries. Use in countries or regions other than those listed above may constitute a violation of law, exposing the operator to legal penalties. *The Bluetooth® word mark and logos are registered trademarks owned by Bluetooth SIG, Inc. and any use of such marks by HIOKI E.E. CORPORATION is under license. *For the latest information about countries and regions where wireless operation is currently supported, please visit the Hioki website.
No. of measurement channels |
Max. 105 ch (use 7 units of LR8510 or LR8511) One or more LR8510 or LR8511 measurement modules are required. Main unit can control up to 7 modules with Bluetooth® wireless technology, mix and match modules as needed |
---|---|
Pulse, digital input | [Pulse totalization] [Rotation count] Not available |
Recording intervals |
100 ms(*2), 200 ms to 1 hour, 16 selections (All input channels are scanned within each recording interval.) (*2) Setting not available when the thermocouple burnout detection setting is on |
Data storage | Internal memory: 8 M-words, Data storage media: SD memory card or USB memory stick (Only data recorded to a genuine HIOKI SD memory card is guaranteed) |
Interface |
LAN: 100BASE-TX, Functions: Data acquisition using bundled software or PC commands, FTP server, FTP client, HTTP server function, or E-mail system USB: USB 2.0 series mini-B receptacle ×1, Functions: Data acquisition using bundled software or PC commands, Transfer data from the SD memory card to a PC via USB drive mode |
Display device | 5.7 inch TFT color liquid crystal display (640 × 480 pixel) |
Functions | Save waveform data in real time to the SD memory card or USB memory stick, Numerical value calculations, Waveform calculations, 4ch alarm output (not isolated, common ground), and others |
Power supply |
[AC adapter] Using the AC adapter Z1008 (100 to 240 V AC, 50/60 Hz), 45 VA Max. (including AC adapter), 15 VA Max. (exclusive of AC adapter) [Internal battery] Using the Battery pack Z1007 (optional accessory), 3 hours of continuous use (at 23 ˚C reference data), 7 VA Max. [External power] 10 to 28 V DC, 15 VA Max. (Please contact your HIOKI distributor for connection cord) |
Dimensions and mass | 230 mm (9.06 in) W × 125 mm (4.92 in) H × 36 mm (1.42 in) D, 700 g (24.7 oz) (excluding Battery pack) |
Accessories | Instruction manual × 1, Measurement guide × 1, SD memory card (2GB) Z4001 × 1, CD-R (data collection software “Logger Utility”) × 1, USB cable × 1, AC Adapter Z1008 × 1 |
Combination status with LabVIEW or MATLAB script
Compatible models | LabVIEW | MATLAB script |
---|---|---|
LR8410-20 | OK | N/A |
Countries and regions where wireless operation is currently supported (LR8410-20, -30)Last update: June 26, 2019
Wireless certification | Japan, United States, Canada, Austria, Belgium, Bosnia and Herzegovina, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Liechtenstein, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey, United Kingdom, Thailand, and Chile |
---|---|
Wireless certification (special) |
Singapore (Order Code: LR8410-20 only) China (Order Code: LR8410-30 only) Taiwan (Order Code: LR8410-20, LR8410-30 only) Indonesia (Order Code: LR8410-20 only) Australia, New Zealand (Order Code: LR8410-20 only) UAE (Order Code: LR8410-20 only) India (Order Code: LR8410-20 only) |
Exempt from the wireless regulations | Viet Nam, Hong Kong, Macao, Myanmar, Russian Federation, Colombia, Pakistan, Georgia, and Kenya |
View more about HIOKI LR8410 on main site